RabbitLink EG2110 Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Sítě RabbitLink EG2110. RabbitLink EG2110 User`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 58
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
RabbitLink (EG2110)
Network Programming Gateway
Users Manual
019–0123 070831–D
Zobrazit stránku 0
1 2 3 4 5 6 ... 57 58

Shrnutí obsahu

Strany 1 - RabbitLink (EG2110)

RabbitLink (EG2110)Network Programming GatewayUser’s Manual019–0123 • 070831–D

Strany 2 - Trademarks

6 RabbitLink (EG2110)By default, the RabbitLink will try to get an IP address using DHCP. (DHCP is a protocol to automatically assign IP addresses to

Strany 3 - TABLE OF CONTENTS

User’s Manual 71.5 RabbitLink CE ComplianceThis section describes the immunity and emissions standards met by the RabbitLink. Design guidelines are g

Strany 4 - Schematics 53

8 RabbitLink (EG2110)EmissionsThe RabbitLink meets the following emission standards with the Rabbit 2000 spectrum spreader turned on and set to the no

Strany 5 - 1. INTRODUCTION

User’s Manual 92. GETTING STARTEDThis chapter shows how to make the necessary hardware con-nections and how to configure the network parameters for t

Strany 6 - 1.1 Overview

10 RabbitLink (EG2110)2.1 RabbitLink Physical Connections1. Attach the RabbitLink board to the plastic enclosure base.Position the RabbitLink board o

Strany 7 - 1.2 RabbitLink Features

User’s Manual 112. Connect the programming cableYou must connect the programming cable to configure network parameters from your PC. Connect the 10-pi

Strany 8 - 4 RabbitLink (EG2110)

12 RabbitLink (EG2110)3. Connect the power supply.Two options are available for powering the RabbitLink. Option 1 is an AC adapter to power supply jac

Strany 9 - 1.4 Software

User’s Manual 132.2 Configuring RabbitLink Network Parameters from your PCThere are two ways to set the basic network parameters for the RabbitLink:

Strany 10 - 6 RabbitLink (EG2110)

14 RabbitLink (EG2110)3. Configure the RabbitLink network parameters. This is done using the serial console commands. Typing the command “show” result

Strany 11 - 1.5 RabbitLink CE Compliance

User’s Manual 152.3 Target System Connections to the RabbitLinkAfter the network addresses have been set, put aside the programming cable and connect

Strany 12 - 8 RabbitLink (EG2110)

RabbitLink (EG2110)Rabbit Semiconductor Inc.www.rabbit.comRabbitLink (EG2110) User’s ManualPart Number 019-0123 • 070831–D • Printed in U.S.A.©2004–20

Strany 13 - 2. GETTING STARTED

16 RabbitLink (EG2110)2.4 Ethernet ConnectionsBefore proceeding, you will need to have either two straight-through Ethernet cables and an Ethernet hu

Strany 14 - 10 RabbitLink (EG2110)

User’s Manual 173. RABBITLINK SOFTWAREThis chapter describes the software functionality available whenusing a RabbitLink. 3.1 Downloading and Debugg

Strany 15 - PC COM port

18 RabbitLink (EG2100)• The Network Address field should contain the IP address of the RabbitLink.• The Control Port field should be set to the TCP po

Strany 16 - Via Screw Terminal

User’s Manual 193.1.6 Troubleshooting Tips• If Dynamic C is unable to establish communication with the RabbitLink, make sure that the RabbitLink is p

Strany 17 - “ERROR <errnum>”

20 RabbitLink (EG2100)3.2 RabbitLink FirmwareThe firmware necessary to operate the RabbitLink with a Rabbit-based target system is loaded at the fact

Strany 18 - 14 RabbitLink (EG2110)

User’s Manual 212. Use the RFU version 2.0 or later to load the DOWNLOAD.BIN firmware or the CLEAR_PARAM.BIN binary image onto the RabbitLink board. 3

Strany 19 - Embedded System

22 RabbitLink (EG2100)

Strany 20 - 2.5 Ready to Go

User’s Manual 23APPENDIX A. SPECIFICATIONSAppendix A provides the specifications for the RabbitLink anddescribes the conformal coating.

Strany 21 - 3. RABBITLINK SOFTWARE

24 RabbitLink (EG2110)A.1 Electrical and Mechanical SpecificationsFigure A-1 shows the mechanical dimensions for the RabbitLink. All measurements are

Strany 22 - <ENTER> when asked

User’s Manual 25Table A-1 lists the electrical, mechanical, and environmental specifications for the RabbitLink.Table A-1. RabbitLink SpecificationsP

Strany 23 - Communications dialog box

User’s ManualTABLE OF CONTENTSChapter 1. Introduction 11.1 Overview...

Strany 24

26 RabbitLink (EG2110)A.2 Conformal CoatingThe area around the crystal oscillator and the battery backup circuit on the RabbitLink has had the Dow Co

Strany 25 - DOWNLOAD.BIN firmware or the

User’s Manual 27APPENDIX B. PLASTIC ENCLOSUREThe plastic enclosure provides a secure way to enclose your RabbitLink board. The enclo-sure itself may

Strany 26 - 22 RabbitLink (EG2100)

28 RabbitLink (EG2110)2. Install light pipes (optional).Light pipes are included in the tool kit so you can see the LEDs on the RabbitLink board once

Strany 27 - APPENDIX A. SPECIFICATIONS

User’s Manual 29Figure B-3. Attach Enclosure Top4. Mount plastic enclosure (optional).Use four #10 screws to attach the assembled plastic enclosure t

Strany 28 - 24 RabbitLink (EG2110)

30 RabbitLink (EG2110)B.2 DimensionsFigure B-4 shows the dimensions for the plastic enclosure.Figure B-4. Plastic Enclosure DimensionsWhen fully ass

Strany 29 - RabbitLink

User’s Manual 31APPENDIX C. SUBSYSTEMSThis appendix describes the principal RabbitLink subsystems.• Serial Communication• Memory• Power Supplies• Res

Strany 30 - A.2 Conformal Coating

32 RabbitLink (EG2110)C.1 RabbitLink Hardware SubsystemsFigure C-1 shows the Rabbit-based subsystems designed into the RabbitLink and shows the paral

Strany 31 - PPENDIX B. PLASTIC ENCLOSURE

User’s Manual 33C.2 Serial CommunicationThe RabbitLink uses two serial ports of the Rabbit 2000 microprocessor.C.2.1 Serial Programming PortsThe Rab

Strany 32 - 28 RabbitLink (EG2110)

34 RabbitLink (EG2110)C.3 MemoryThe RabbitLink has SRAM and flash memory devices. The Dynamic C BIOS handles dif-ferent standard RAM and flash memory

Strany 33 - User’s Manual 29

User’s Manual 35C.4 Power SuppliesPower is supplied to the RabbitLink board from an external source either through jack J4 or through screw terminal

Strany 34 - B.2 Dimensions

RabbitLink (EG2110)Appendix C. Subsystems 31C.1 RabbitLink Hardware Subsystems ...

Strany 36 - C.1.1 Pinouts

User’s Manual 37APPENDIX D. PROGRAMMING CABLEThis appendix provides technical information about the Rabbit2000 microprocessor when connecting the Rab

Strany 37 - C.2 Serial Communication

38 RabbitLink (EG2110)The DIAG ConnectorThe DIAG connector is used to configure network parameters for the RabbitLink. It is also used to treat the pr

Strany 38 - C.3 Memory

User’s Manual 39APPENDIX E. SERIAL CONSOLECOMMANDSThis appendix describes the RabbitLink serial console commands.The serial console was designed to b

Strany 39 - C.5 Reset Generator

40 RabbitLink (EG2110)E.1 Configuration CommandsThese commands are used to set network parameters and to password-protect the RabbitLink.set consbaud

Strany 40 - 36 RabbitLink (EG2110)

User’s Manual 41set passphrase This command will prompt for a passphrase twice to confirm that the passphrase was en-tered correctly. The characters a

Strany 41 - PPENDIX D. PROGRAMMING CABLE

42 RabbitLink (EG2110)E.2 Variables CommandsThe RabbitLink serial console has the ability to handle SSI (Server Side Includes) vari-ables. These vari

Strany 42 - 38 RabbitLink (EG2110)

User’s Manual 43list variablesThis command lists all the variables by name and type that are stored in the flash file system on the RabbitLink. reset

Strany 43 - COMMANDS

44 RabbitLink (EG2110)E.3 File Commandsdelete <filename>Deletes the specified file from the flash file system on the RabbitLink.filename Identi

Strany 44 - E.1 Configuration Commands

User’s Manual 45put <filename><size>This command sends a binary file to the flash file system on the RabbitLink. There is a time-out for t

Strany 45 - User’s Manual 41

User’s Manual 11. INTRODUCTIONThis chapter introduces the RabbitLink Network ProgrammingGateway and describes its features.Rabbit-based embedded syst

Strany 46 - E.2 Variables Commands

46 RabbitLink (EG2110)E.4 E-Mail Commandsmail <e-mail address><subject><body><ctrl-D>The mail command sends an e-mail via the

Strany 47 - User’s Manual 43

User’s Manual 47E.5 Other Console Commandsecho <on | off>This command toggles the echoing of characters.help [filename]This command displays th

Strany 48 - E.3 File Commands

48 RabbitLink (EG2110)E.6 RabbitLink Console Function Call (prior to Dynamic C 7.20)The RabbitLink serial console may be accessed via the serial port

Strany 49 - User’s Manual 45

User’s Manual 49ConsoleFinishint ConsoleFinish(long timeout);This function finishes receiving data from the RabbitLink serial console by blocking for

Strany 50 - E.4 E-Mail Commands

50 RabbitLink (EG2110)E.7 Example Using the RabbitLink Console Function Callmain() {// first methodSendToConsole("set ip 10.10.2.102\n", 19

Strany 51 - E.5 Other Console Commands

User’s Manual 51INDEXAAC adapter ... 12Bbroadcast packet ... 18CCE compliancedesign guidelines ...

Strany 52 - SendToConsole

52 RabbitLink (EG2110)

Strany 53 - ConsoleFinish

User’s Manual 53SCHEMATICS090-0168 RabbitLink (EG2110) Schematicwww.rabbit.com/documentation/schemat/090-0168.pdf090-0128 Programming Cable Schematicw

Strany 55 - User’s Manual 51

2 RabbitLink (EG2110)1.1 OverviewMicroprocessor boards with a Rabbit microprocessor use a standardized programming connector. Using this connector it

Strany 56 - 52 RabbitLink (EG2110)

User’s Manual 31.2 RabbitLink FeaturesThe following is a list of RabbitLink hardware and software features. • Rabbit® 2000 microprocessor operating a

Strany 57 - SCHEMATICS

4 RabbitLink (EG2110)1.3 Development and Evaluation ToolsThe RabbitLink board comes with two program download cables. These cables connect a Rabbit-b

Strany 58

User’s Manual 51.4 SoftwareThe RabbitLink board is shipped with firmware already installed in the flash memory. The rows in the following table show

Komentáře k této Příručce

Žádné komentáře